Article List
- 2015Indonesia international LED lighting fair2015.05.20-05.22 2015Indonesia international LED lighting fair Place:Jakarta IndonesiaExhibition May 20, 2015
- 2016Tanzania international power&energy Exhibition2016.04.07-7.092016Tanzania international power&energy Exhibition Place:Dar-es-Salaam TanzaniaExhibition April 07, 2016
- 2015Peru International Power and energy Exhibition2015.08.06-8.08 2015Peru International LED light fair Place:Lima,PeruExhibition August 06, 2015
- The analysis of oil discharge from PVC insulation and sheath of cablesPVC insulated and sheathed cables have different levels of oil discharge on the surface during use, causing a big loss to the company as a serious quality accident. "Oil discharge" means that some of the incompatible components in the PVC migrate slowly from the product to the surface and graduallyExhibition June 15, 2019
- Flex Test for Lift CablesGiven the type of installations and equipment where lift cables are used, they need to be able to withstand constant and rapid movement and flexing without failure. This test is specifically designed to replicate that rapid back and forth flexing under electrical load to determine their suitabilityTest Lab March 27, 2019
- Crimp and Lug TestBS EN 61238-1 is the standard that covers compression and mechanical connnectors for power cables at rated voltages of up to 36kV. There are two classes defined within the standard - Class A which includes short circuit testing and Class B which does not include this testing.Crimp testing and lug teTest Lab March 27, 2019
- Cable Smoke Density Test- 3 meter Cube TestCable Smoke Density Testing to BSEN 61034 (previously BS EN 50268) is commonly known as the 3 metre cube test. It is designed to determine the volume of smoke generated when cables are burned.The Cable Smoke Density Test is primarily performed on Low Smoke Zero Halogen cables, and is conducted insidTest Lab March 27, 2019
- Gas Emissions Test for CablesGas Emissions testing, more formally known as the test of gases evolved, is to meet the requirements of IEC 60754 (previously BS EN 50267-2). There are two parts to the test: the determination of halogen acid gas content and the determination of acidity by pH measurement.GAS EMISSIONS TESTING: DETERTest Lab March 27, 2019
- Cable Spike TestSpike Testing for cables is designed to prove that a cable with a wire screen is capable of withstanding the maximum designated voltage in the event of a sudden surge in current.The copper wire screen (CWS) or aluminium wire screen (AWS) act as an earthing wire for the phase conductors. Testing methTest Lab March 27, 2019
- Sheath Resistance TestSheath Resistance testing is a key onsite diagnostic test for identifying potential cable faults. Commonly known as a Megger Test, it uses a Megohmmeter to measure the resistance of the cross-linked or thermoplastic compound to an applied DC voltage. It should be noted that this test is designed toTest Lab March 27, 2019